Measurement

Strain Gauge type Pressure Transducer

4mA to 20mA current output type

TP-IR

Feature
Including current output amp.(4 to 20 mA)
Witstand noise
TP-IR
| Main specifications |
Main specifications
Model TP-IR
Safe Over Load Rating 150%R.C.
Rated Output 4 to 20mA(Load <1kohms)±0.3%
Nonlinearity 0.3%R.O.
Hysteresis 0.3%R.O.
Repeatability 0.3%R.O.
Maximum Excitation DC15V to 30V(Approx. 40mA)
Insulation Resistance >1000M ohms
Signal to Noise ratio >50dB(Approx. 16mVp-p)
Frequency response DC to 1kHz
Load reistance 0 to 500ohms
Operating Temperature Range -10ºC to 50ºC
Storage Temperature Range -10ºC to 60ºC
Temperature Effect on Zero Signal 0.3%R.O./10ºC
Temperature Effect on Sensitivity 0.3%R.O./10ºC
Residual Unbalance ±0.3%R.O.
Installation screw G3/8(PF3/8)
Plug included
Connecting diagram
??? TP-IR
Rated capacity
1MPa(10.2kgf/cm2)
2MPa(20.4kgf/cm2)
5MPa(51kgf/cm2)
10MPa(102kgf/cm2)
20MPa(204kgf/cm2)
30MPa(306kgf/cm2)
50MPa(510kgf/cm2)
Figure of dimensions (mm)
Figure of dimensions TP-IR
Figure of dimensions TP-IR
Support Menu