Measurement

General pressure monitoring type

Strain Gauge type Pressure Transducer

TP-HVR

Feature
Small,High temperature type,All stainless steel
TP-HVR
| Main specifications |
Main specifications
Model TP-HVR
Safe Over Load Rating 120%R.C.
Rated Output Approx.1mV/V(1MPa)
1.5mV/V(2MPa to 50MPa)
Nonlinearity 0.5%R.O.
Hysteresis 0.5%R.O.
Repeatability 0.3%R.O.
Maximum Excitation 6V
Input Resistance 370ohms±7.5ohms
Output Resistance 350ohms±7.5ohms
Insulation Resistance >1000M ohms(DC50V)
Operating Temperature Range -10ºC to 150ºC
Storage Temperature Range -20ºC to 165ºC
Temperature Effect on Zero Signal 0.08%R.O./10ºC
Temperature Effect on Sensitivity 0.1%R.O./10ºC
Cable Φ4,4-core teflon coated cable, 5m direct connected
Connector PRC03-12A10-7M10.5
Rated capacity Natural frequency Weight (Approx)
1MPa(10.2kgf/cm2) 38kHz 40g
2MPa(20.4kgf/cm2) 60kHz 40g
5MPa(51kgf/cm2) 95kHz 40g
10MPa(102kgf/cm2) 160kHz 40g
20MPa(204kgf/cm2) 150kHz 110g
50MPa(510kgf/cm2) 240kHz 110g
Figure of dimensions (mm)
Figure of dimensions TP-HVR
Figure of dimensions TP-HVR