Measurement

Strain Gauge Type Load Cell

TT-OR

March,2007 Discontinued
Feature
Fracture protective system
Maximum safe load 500%
TT-OR
| Main specifications |
Main specifications
Model TT-OR
Safe Over Load Rating 150%R.C.
Rated Output 2mV/V±0.5%
Nonlinearity 0.05%R.O.
Hysteresis 0.05%R.O.
Repeatability 0.02%R.O.
Maximum Excitation 20V
Input Resistance 700ohms±10ohms
Output Resistance 700ohms±10ohms
Insulation Resistance >1000Mohms
Operating Temperature Range -10ºC to 75ºC
Storage Temperature Range -30ºC to 80ºC
Temperature Effect on Zero Signal 0.03%R.O./10ºC
Temperature Effect on Sensitivity 0.03%R.O./10ºC
Cable Φ8,4-core shielded,5m direct connected
  Fracture protective system
Main body materials Nickel-chrome-molybdenum steel
Rating capacity
1kN(102kgf)
2kN(204kgf)
5kN(510kgf)
10kN(1.02tf)
20kN(2.04tf)
Figure of dimensions (mm)
Figure of dimensions TT-OR
Support Menu