Measurement

Color graphic Digital Indicator

TD-275T

TD-275T
| Main features | Main specifications | Option |
TD-275T is a digital indicator unit for viewing such as force, pressure, torque data as a waveform and numerical data. It is connected with load-cell(strain gauge type)

Measured data can be stored to CF card (CSV format) and utilized for quality management.Also it is possible to analyze the details using PC at the measuring sight.

RS-232C interface, LAN interface, D/A conveter card are provided as options.These provide monitoring system using PC or Workstation.
And these have a hold function, so these can be used at a production site for instrumentation indicator for load-cell.

TD-275T has a capability of reading TEDS(transducer electronic data sheet) parameter.So setting time will be shorter and error for settings can be avoided using TEDS type transducer.Also it is possible to measure accurately.
Main features
3.5inch STN Color LCD modle
Numeric data / waveform available
TEDS(Transducer Electronic Data Sheet)
CF card slot standard deployment(CF card is sold separately)
RS-232C,LAN,D/A converter(Option) (Specify one when you order)
Power supply:AC100V to 240V (3P terminal)
Dimension(W×H×D):Approx. 105mm×108mm×145.1mm(excluding tang)
Weight:Approx. 1.05kg(excluding Option)
Main specifications
■Load Sensor input
Input/Range Strain gauge type sensor 0.5 to ±3.0mV/V
Input connector Screw connection-type terminal(pitch5.08mm 12P)
Excitation Voltage DC2.5V±10%/10V±10%
Current 30mA
Calibration method Equivalent Input/TEDS/Real Load
Band of calibration 0.5 to 3.0mV/V
Accuracy of calibration < 0.1%F.S
Zero balancing 0 to ±2.0mV/V
Accuracy/Nonlinearity < 0.02%F.S±1digit(Input > 1mV/V)
Zero drift < 0.5μV/ºC(Input conversion value)
Gain drift < 0.01% F.S/ºC
Analog filter Selectable 10,30,100Hz(default),300Hz
Low pass filter:Attenuation -6dB/OCT
A/D conveting rate 2000times/sec.
Quantization 16bits
TEDS function IEEE 1451.4 Class 2 mix mode interface
Peak-hold function Digital hold
Analog output Approx. 1.0V(per sensor input 1.0mV/V)
■Other specifications
Display/Operation 3.5inch STN Color LCD modle (320×240dot)
Operation Touch panel
Max value Load 0 to ±9999
Displacement 0 to ±9999
Decimal point Selectable display position
Display timing 3times/sec.
Time axis setting 0.5/1/2/5/10sec.
Indication item Digital load value,Waveform,Setting,Distortion,etc.
Display item Status Comparison judgment value setting Load:HI/LO/HI-HI/LO-LO limit
Displacement:HI/LO limit
Hold function Inflection point,Sample,Peak/maximum value,Minimum value
Others function setting Analog/Digital filter,Digital zero,Measurement start/end condition
Graph setting,CF card setting,Minimum scale,etc.
Measurement work setting memory Selectable 16kinds(Comparison value judgment,Hold setting,start/end condition)
Clock function Management of data by a real-time clock
Judgment output signal Load HI/LO/HI-HI/LO-LO,GO Output,Each a contact
Displacement HI/LO,GO Output,Each a contact
Point of contact Rating voltage 30V
Current 50mA
Insulation Photocoupler
Control input/output signal Measurement start/end,Sample hold,Reset,Digital Zero
Work change input,Measurement completed Output
Connector Multi-electrode connector(FCN-365P032-AU)
Rated Input signal Dry contact Input(Contact,Transistor opening collector,etc.),Outflow current:Approx. 10mA
Output signal Rated Voltage 30V
Current 50mA
Insulation Photocoupler
CF card Saving data to CF card on CSV format.Saving load data from start to stop or Automatic start level to judgement output.The result also saved.
Power supply AC100V to 240V (3P terminal) Approx. 15W
Environment Temperature Compensated range:0ºC to 40ºC Storage range:-20ºC to 60ºC
Humidity <85%RH(Non-condensing)
Dimension(W×H×D) Approx. 105mm×108mm×145.1mm(excluding tang)
Weight Approx. 1.05kg(excluding Option)
Accessory(each1) Manual(CD-ROM),Outlin manual,Sensor input connector(Phoenix Contact MC1.5/12-STF-5.08),Control input/output connector/plug(FUJITSU)
(connector:FCN-361J032-AU,cover:FCN-360C032-B)
Regulations EMC VCCI(classA)
EN55011(classA),EN61326-4-2,3,4,5,6,8,11, EN61000-3-2,3
Safety EN61010-1
Figure of dimensions(mm)
Figure of dimensions TD-275TFigure of dimensions TD-275T
Option
*■Only one option can be installed (excluding CF card)
■RS-232C
(Specify option when you order)
Signal level RS-232C Conformity
Electrical transmission distance Approx. 10m
Transfer method Start/Stop synchronization,Full duplex
Transfer speed 4800/9600/19200/38400/57600/115200bps
Bit pattern Start bit 1bit
Character length:8bit
Stop bit:1bit
Parity bit:Selectable from Nothing/Odd number/Even number
Cord ASCII
■LAN
(Specify option when you order)
LAN Interface 100BASE-TX/10BASE-T Automatic recognition
Connections 1
Connector RJ-45
LED Display Link/Activity LANTRONIX XPort use
■D/A converter
(Specify option when you order)
  D/A Zero setting,(For a digital value by full scale setting)
Voltage output 0 to ±10V(Load <2kohms)
Current output 4 to 20mA(Load <500ohms)
CAL function 0 or 10V cal signal and 4 or 20mA cal signal can be output.
Support Menu