Measurement

Digital Indicator

TD-270

March,2007 Discontinued
TD-270
| Main specifications | Option |
Main specifications
Sensor excitation 10V, 5V, 2.5V DC(digital adjustment)
Output current: Within 120mA
4-wire(Up to four 350ohms load cells can be connected.)
Signal input range -3.0 to +3.0mV/V
Zero and gain adjustment Performed by digital computation
Accuracy Non-linearity Within 0.02%FS±1 digit(at a 3.0mV/V input)
Zero drift Within 0.5µV/ºC RTI
Gain drift Within 0.01%/ºC
A/D converter Rate 2000 times/sec.
Resolution 16 bits(binary)
Analog filter 10Hz, 30Hz, 100Hz, 300Hz(digital adjustment)
Display STN color LCD module(display area: 75mm×56mm)
320×240 dots
Indicated value: ± 99999(5-digit)
Equivalent input calibration Range 0.5 to 3.0mV/V
Error Within 0.03%FS
Hold functions 1)Sample hold
2)Peak hold
3)Valley hold
4)Peak-to-peak hold
5)Relative maximum hold
6)Relative minimum hold
7)Inflection point hold
Period setting(all period, external signal, time, time with trigger)is available for 2)to 4).
Combinations allow selection from 16 hold types.
Comparison functions   External output
HI-HI limit HH
LO-LO limit LL
  OK
HI limit HI
LO limit LO
Calibration value selection Four calibration values can be stored in memory and switched.
Option
BCD data output
(TD-2703)
Open-collector output
Output rate
Can be selected from 1 time/sec., 10 times/sec., 100 times/sec.
and 1000 times/sec.
RS-232C communication interface
(TD-2704)
Start/stop system
Baud rate: 1200bps to 19200bps
RS-485 communication interface
(TD-2710)
Communication conditions are the same as RS-232C.
D/A converter
(TD-2707)
Voltage output 0V to 10V
Current output 4mA to 20mA
  Zero output and full scale output can be digitally adjusted.