Return to HomeProductsDownloadAbout DSPDSales
>> Magnetic >> FD-235HF/FD-235HG


One-inch high design
Operates on +5v power
A choice of models to match your system requirements :
FD-235HF ( 2MB / 1MB ), FD-235HG ( 2MB / 1.6MB / 1MB )
Long-life, precise, reliable brushless DD motor
SPECIFICATION

FD-235HF

FD-235HG

Data transfer rate ( kbits/s ) 500/250
Data capacity
( MBytes,Unformatted )
2/1( unformatted ) 2/1.6/1
Innermost Track
Bit Density
17434 , 8717 ( dpi ) 17434 , 14528 , 8717
( dpi )
Rotation speed min-1( rpm )
300
300/360/300
Track/Disk 160
Track density ( tpi ) 135
Number of cylinders 80
Average access time ( msec. ) 94
Track to track time ( msec. ) 3
Settling time ( msec. ) 15
Recording method FM or MFM
Media 3-1/2 inch micro floppy disk
High density ( 2HD ) or Normal density ( 2DD )
Starting time 480msec. or less
Average Latency Time 2MB,1MB mode : 100ms
1.6MB mode : 89.3ms
Index
1 per disk revolution
Detetion Interval : 2MB, 1MB mode : 200ms±1.5%
1.6MB mode : 166.7ms±1.5%
MTBF 30,000 hours or more
MTTR When failure, the FDD should be replaced in unit of the drive.
Safety standard Complies with UL,CSA,TUV and CE
Ambient Temperature
Operating : 4 - 51.7oC ( 39 - 12oF )
Storage : -22 - 60oC ( -8 - 140oF )
Transportation : -40 - 65oC ( -40 - 149oF )
Relative Humidity
Operating : 20 - 80% ( non-condensing )
Storage : 5 - 90% ( non-condensing )
Transportation : 5 - 95% ( non-condensing )
Vibration
Operating : 14.7m/s2 (1.5G) or less (10 - 100Hz, 1oct/min)
9.8m/s2 (1.0G) or less (100 - 200Hz, 1oct/min)
4.9m/s2 (0.5G) or less (200 - 600Hz, 1 oct/min)
Transportation : 19.6m/s2 (2G) or less (10 - 100Hz, 1/4oct/min)
Shock
Operating : Write & read : 49m/s2 (5G) or less
Read only : 98m/s2 (10G) or less
Transportation : 686m/s2 (70G) or less
(11ms,1/2 sine wave)
Power Requirements DC+5V ±10% ( DC+12V : Not required )
Allowable ripple voltage : 100m Vp-p or lass
Power Consumption Stand-by mode : 40mW typ
Read/Write : 1.50W typ.
Dimensions 101.6W X 25.4H X 145D ( mm )
Weight 410g (0.90lbs) typical
* Specifications apply when the MFM recording method is used.
* Each value is settled under a certain condition. Please refer the specification for more details.




Copyright (C) TEAC Corporation. All rights reserved.